The following procedure shall be implemented June 1, 1995. This means that any Product Approval submittal received in this office after said date shall be evaluated to this procedure.
To begin with, only those anchors and fasteners that were tested shall be approved.
For Roll-Up Doors:
Specimen 1 test to PA201 & PA203 on 2000 psi concrete column on both sides and qualify two types of anchors.
Specimen 2 test to PA201 & PA203 on A36 steel column on both sides and qualify two types of fasteners.
Specimen 3 test to PA201 & PA203 on C-90 masonry block with 2000 psi grout column on both sides and qualify two types of anchors.
For Sectional Doors:
Specimen 1 test to PA201 & PA203 on 2"x6" or larger PT#3 Southern Pine wood buck on both sides and qualify two types of anchors.
Specimen 2 test to PA201 & PA203 on C-90 masonry block with 2000 psi grout column on both sides and qualify two types of anchors.
Specimen 3 test to PA201 & PA203 on 2000 psi concrete column on both sides and qualify two types of anchors.
In both cases mentioned above, each test will qualify one structural substrate application and two types of fasteners/anchors. Other types of substrates may require additional testing.
When down sizing any of the mentioned doors, the spacing of the anchors shall never exceed that which was tested.
The requirements of PA202 can be performed in any type of substrate mentioned above and with any of the fasteners/anchors used for PA201 & PA203.
The test report shall describe the anchor/fastener type, location, embedment, spacing, type of column substrate and specification, etc. Calculations verifying the anchor/fastener used and recommended method of installing 2'x6" or larger buck to concrete/masonry block shall be submitted.
Please note that if you wish to only receive approval for one column substrate, then the three required tests for PA201 and PA203 shall be performed on that substrate. You may still qualify different anchors/fasteners on said column substrate.
|